DR CONFIG REPLICATION FAILED: NVMe over Fabrics is not supported
- Views:
- 476
- Visibility:
- Public
- Votes:
- 0
- Category:
- metrocluster
- Specialty:
- MetroCluster
- Last Updated:
- 6/19/2024, 8:17:44 AM
Applies to
- MetroCluster
- ONTAP 9
- Degraded SVMs reported
- NVMe protocol
Issue
metrocluster vserver show
reports one of the following errors:
Cluster : ClusterA
Vserver : SVM1
Partner Vserver : SVM1-mc
Stream : xxxxxxae-xxxx-xxec-axxx-dxxxeaxxfdxx
Configuration State : degraded
Failed Replication Reason : Apply failed for Object: vifsbyname Method: baseline. Reason: Cannot configure SAN LIF "lif_SVM1" on Vserver "SVM1-mc". Reason: Vserver "SVM1-mc" must have an NVMe service to execute this operation. Use the "vserver nvme create -vserver SVM1-mc" command to create the NVMe service for the Vserver.
Failed Replication Reason : Apply failed for Object: vserver_ui Method: baseline. Reason: NVMe over Fabrics is not supported in a Vserver with MetroCluster configured.
- When you try to add the NVMe protocol you see the follow error:
cluster1::vserver> add-protocols -vserver NVMe -protocols nvme
Error: command failed: NVMe over Fabrics is not supported in a Vserver with MetroCluster configured.