Applies to

  • MetroCluster FC
  • Brocade Switch
  • ONTAP 9

Issue

  • A Brocade switch was reporting persistent hardware faults, eventually entering a “faulty” state.
  • The following errors can be seen on the supportshow:
FCN000001:admin> switchshow
switchName:     FCN000001
switchType:     162.5
switchState: Faulty
switchMode:     Native
switchRole:     Faulty
switchDomain:   5
switchId:       fffc05
switchWwn: 10:00:88:94:71:c1:d3:78
zoning:         ON (CFG_G620_FAB_1_RCF_9_2b)
switchBeacon:   OFF
FC Router:      OFF
HIF Mode: OFF
errdump -a:
2026/03/27-19:13:45 (CEST), [C4-1045], 8144, CHASSIS, INFO, BrocadeG620,Single parity error detected in ftb statistics memory, slot 0 index 0
2026/03/27-19:13:45 (CEST), [C4-1010], 8145, CHASSIS, CRITICAL, BrocadeG620, S0,C0: Above normal hardware errors were observed: fault1:0xa, fault2:0xa thresh2:0xb000000a.
2026/03/27-19:13:45 (CEST), [C4-1056], 8146, CHASSIS, CRITICAL, BrocadeG620, Chip in Slot 0, Chip 0 getting faulted with reason 52.
2026/03/27-19:13:45 (CEST), [EM-1134], 8147, FFDC | CHASSIS, ERROR, BrocadeG620, Switch set to faulty, rc=20015.
2026/03/27-19:13:45 (CEST), [RAS-1001], 8148, CHASSIS, INFO, BrocadeG620, First failure data capture (FFDC) event occurred.
 
  • Event logs:
ERROR fcvi.qlgc.ioErr: FC-VI adapter: FCVI driver on port 5a/5c received IO error. Status=FW detected response error (status code=0x121), FCVI opcode=WriteRequest (0x1), QPname=WAFL, QPindex=4/10, Remote node's systemid=

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.