Skip to main content
NetApp Knowledge Base

Does Vscan synchronize in SVM-DR?

Views:
Visibility:
Public
Votes:
0
Category:
ontap-9
Specialty:
dp
Last Updated:

Applies to

  • ONTAP 9
  • NetApp SVM Disaster Recovery (SVM-DR)
  • Vscan

Answer

No, Vscan settings do not synchronize in SVM-DR. Need to configure Vscan manually on the destination side.
NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.