Answer

  • In SVM DR, LUN WWIDs are not preserved.
  • DR destination LUNs are created as new LUN objects under a different SVM and receive new WWIDs.
  • After a failover, hosts see the LUNs as new devices.
  • Failover requires reconfiguration:   
    1. Recreate LUN mappings on the DR SVM.
    2. Rescan storage on hosts.
    3. Update host settings (for example, multipathing or application configurations).
NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.