Skip to main content
NetApp Knowledge Base

The 'sanlun lun show -p' command reports stale paths

Views:
67
Visibility:
Public
Votes:
0
Category:
ontap-9
Specialty:
SAN
Last Updated:

Applies to

  • ONTAP 9.3P21
  • AIX 7.2
  • Host Utility 6.1

Issue

  • The sanlun lun show -p command reports stale paths.

Example:

[root@dbsvr01:/]# sanlun lun show -p

                    ONTAP Path: SVR01:/vol/vol06/lun06
                           LUN: 6
                      LUN Size: 600.1g
                   Host Device: hdisk9
                          Mode: C
            Multipath Provider: AIX Native
        Multipathing Algorithm: round_robin
--------- ----------- ------ ------- ---------------------------------------------- ----------
host      vserver     AIX                                                           AIX MPIO
path      path        MPIO   host    vserver                                        path
state     type        path   adapter LIF                                            priority
--------- ----------- ------ ------- ---------------------------------------------- ----------
up        secondary   path2  fcs3    SVR004_1c                                      1
up        primary     path3  fcs3    SVR005_1c                                      1
up        secondary   path0  fcs1    SVR004_1c                                      1
up        primary     path1  fcs1    SVR005_1c                                      1
down                  path4  fcs0                                                   1    
down                  path5  fcs0                                                   1
down                  path6  fcs2                                                   1
down                  path7  fcs2                                                   1
up        secondary   path8  fcs0    SVR004_2c                                      1
up        primary     path9  fcs0    SVR005_2c                                      1
up        secondary   path10 fcs2    SVR004_2c                                      1
up        primary     path11 fcs2    SVR005_2c                                      1

  • The lspath command also shows stale paths.

Example:

[root@dbsvr01:/]# lspath

    Enabled hdisk9  fscsi1
    Enabled hdisk9  fscsi1
    Enabled hdisk9  fscsi3
    Enabled hdisk9  fscsi3
    Missing hdisk9  fscsi0
    Missing hdisk9  fscsi0
    Missing hdisk9  fscsi2
    Missing hdisk9  fscsi2
    Enabled hdisk9  fscsi0
    Enabled hdisk9  fscsi0
    Enabled hdisk9  fscsi2
    Enabled hdisk9  fscsi2
    Enabled hdisk9  fscsi3
    Enabled hdisk9  fscsi3
    Enabled hdisk9  fscsi1
    Enabled hdisk9  fscsi1
    Missing hdisk9  fscsi0
    Missing hdisk9  fscsi0
    Missing hdisk9  fscsi2
    Missing hdisk9  fscsi2
    Enabled hdisk9  fscsi0
    Enabled hdisk9  fscsi0
    Enabled hdisk9  fscsi2
    Enabled hdisk9  fscsi2

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.