Issue
- After Veeam backup reconfiguration and testing datastores and or virtual machines become inaccessible
- Multiple VMware VMs became inaccessible and failed to boot.
- Multiple VMs unable to be powered off and are not responding.
- Multiple VMs unable to boot with "File system specific implementation of Ioctl[file] failed"
- VMFS heartbeat timeouts and application crashes were observed on ESXi hosts.
Log Output Examples:
- ONTAP Audit Log:
PATCH /api/storage/volumes/ab12a23:{ "restore_to.snapshot.name": "daily.2025-1-1_0000" } - ESXi Log:
[vmfsCorrelator] [vob.vmfs.heartbeat.timedout] datastore1[UserWorldCorrelator] [esx.problem.application.core.dumped] An application (/bin/vmx) running on ESXi host has crashed.
- VM Power-On Error:
Filesystem specific implementation of GetObject[fS] failed.Moduledisk poweron failed. Cannot open disk or one of its snapshot disks it depends on. Could not open or create change tracking file.