Issue
- All Fibre Channel (FC) LUNs from NetApp FAS8200 were not visible on Hyper-V servers after a data center migration.
- Hyper-V virtual machines could not power on due to lack of FC communication.
- FC adapters and initiators were not detected by ONTAP (
fcp adapter showandvserver fcp initiator showreturned empty). - Storage-side configuration and LUN mappings appeared correct, but no FC initiator logins were seen.
- FC LIFs showed status up/- (
admin up, operational status indeterminate). - FC ports reported PortSpeed: 0Gb/s, PortStatus: offline.
- Error when creating new LIF on FC port:
Error: command failed: 0g is an invalid port on node IOB-CHN-SAN01.
- Issue began immediately after data center migration.