IO Error reported on ESXi due to faulty host end sfp
Applies to
- Ontap 9
- Brocade Switch
- ESXi
Issue
- IO errors reported on ESXi.
C3 discard
errors reported on the host connected switch port.
portstatsshow
output snippet-
er_rx_c3_timeout 20876 Class 3 receive frames discarded due to timeout
er_tx_c3_timeout 0 Class 3 transmit frames discarded due to timeout
er_unroutable 0 Frames that are unroutable
er_unreachable 0 Frame with unreachable destination
er_other_discard 20876 Other discards
- Rx power reported on the switch port connected to host is not in the recommended range.
RX Power: -10.7 dBm (84.6 uW)
TX Power: -1.1 dBm (770.3 uW)
- Isolate the issue further by following below steps-
- Connect the cable from server to switch to a free switch port.
- If Issues follows to the new switch port, then the faulty component could be either server end sfp or cable.
- Start with cable replacement between the server and the switch port.
- If issues persists post cable replacement between server and switch , then proceed with the solution.