Issue

  • "CHECK MEDIUM ERROR" is received on host end while accessing the FC LUNs.

Check-medium-error.png

  • Recent changes have been made to the network environment.
  • Below object.store.unavilable errors are seen in EMS logs

[?]  Mon Jun 10 08:37:22 -0500 [node-07: OscHighPriThreadPool: object.store.unavailable:EMERGENCY]: Unable to connect to the object store "fabricpool_xyz" from node 020xcxc90-xxxx-11ea-95bf-00xcxcxce4602. Reason: Inter-cluster LIF not configured.
[?]  Mon Jun 10 08:37:12 -0500 [node-08: OscHighPriThreadPool: object.store.unavailable:EMERGENCY]: Unable to connect to the object store "fabricpool_xyz" from node 02axcxc3e-xxxx-11ea-bea1-00xcxcx4972. Reason: Inter-cluster LIF not configured.
[?]  Mon Jun 10 08:36:25 -0500 [node-11: OscHighPriThreadPool: object.store.unavailable:EMERGENCY]: Unable to connect to the object store "fabricpool_xyz" from node 3c1xcxc8b-xxxx-11ee-bcd8-d039xcxc18b9. Reason: Inter-cluster LIF not configured.
[?]  Mon Jun 10 08:36:17 -0500 [node-12: OscHighPriThreadPool: object.store.unavailable:EMERGENCY]: Unable to connect to the object store "fabricpool_xyz" from node 61b0xcxcb-xxxx-11ee-882a-d03xcxxc18c9. Reason: Inter-cluster LIF not configured.

  • IC LIFs being removed error messages seen in EMS logs.

[?]  Mon Jun 10 08:37:21 -0500 [node-07: vifmgr: vifmgr.lifBeingRemoved:notice]: LIF node-07_icl07 (on virtual server 42cxcx95), IP address 172.23.xx.yy, is being removed from node node-07, port a0a-1xx1.
[?]  Tue Jun 11 00:48:38 -0500 [node-07: vifmgr: vifmgr.lifsuccessfullymoved:notice]: LIF node-07_icl07 (on virtual server 42xcxcx95), IP address 172.23.xx.yy, is now hosted on node node-07, port a0a-1xx1.

 

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.