Event log show error netif.linkErrors
Applies to
ONTAP 9
Issue
- EMS log report the following error every hour:
[cluster1-01: intr: netif.linkErrors:error]: Excessive link errors on network interface x. Might indicate a bad cable, switch port, or NIC, or that a cable connector is not fully inserted in a socket. On a 10/100 port, might indicate a duplex mismatch.
- This can be reported for different ports and nodes.
- Ifstat output can also show increasing synchronized Total and CRC errors:
-- interface e0b (3 days, 2 hours, 26 minutes, 34 seconds) --
RECEIVE
Total frames: 1529m | Frames/second: 5707 | Total bytes: 13273g
Bytes/second: 49528k | Total errors: 24795 | Errors/minute: 6
Total discards: 0 | Discards/minute: 0 | Multi/broadcast: 64771
Non-primary u/c: 0 | CRC errors: 24795 | Runt frames: 0
Fragment: 0 | Long frames: 0 | Jabber: 0
Length errors: 0 | No buffer: 0 | Xon: 0