SP duplicate IP alert in AFF A400, AFF C400, FAS8300, FAS8700 system
Applies to
- AFF-A400, AFF-C400
- ASA-A400, ASA-C400
- FAS8300, FAS8700
- Baseboard Management Controller (BMC)
- ONTAP 9
Issue
- During ONTAP upgrade, BMC is not reachable and the system shows SP duplicate IP alerts (sp.dup.ip):
[node1: spmgrd: sp.dup.ip:error]: SP IP address 10.x.x.x in use by another system.
[node1: spmgrd: sp.dup.ip:error]: SP IP address 10.x.x.x in use by another system.
[node1: spmgrd: sp.dup.ip:error]: SP IP address 10.x.x.x in use by another system.
- No duplicate IP address is found in the network
- After ONTAP upgrade, the
sp.dup.ip
alerts remain - The issue can also occur after a BMC firmware update or after a BMC reboot
- BMC might reboot with a "HW watchdog timeout happened last time!" error and then reports the duplicate IP address:
SP-LATEST-STATISTICS:
IPMI_Main.c main start 23.15 12.59
IPMI_Main.c main after sync time 27.11 14.19 Sat Jun 22 19:47:55 GMT 2024
BMC init unknown:Sat Jun 22 19:48:11 GMT 2024
GPIO boot : Primary
Physical slot : #1
Primary env : active:#1 inactive:#1
Last boot error : HW watchdog timeout happened last time!