Skip to main content
NetApp Knowledge Base

SP auto upgrade failed during pre-check

Views:
132
Visibility:
Public
Votes:
0
Category:
ontap-9
Specialty:
HW
Last Updated:

Applies to

  • ONTAP 9
  • FAS/AFF/ASA
  • Service Processor

Issue

  • SP auto-update failed with the below errors and SP IP is not pingable:
  • EMS-LOG-FILE.GZ log:
 [?]  Mon Jul 29 21:56:37 -0700 [Node-01: servprocd: sp.servprocd.upd.error:error]: SP update error: SP Firmware network auto-update could not be scheduled..
 [?]  Mon Jul 29 22:16:58 -0700 [Node-01: servprocd: sp.servprocd.upd.error:error]: SP update error: SP Firmware network auto-update could not be scheduled..
 
  • SP-MGMT-MLOG-TXT log:
00000017.02338b6d 0e63406a Mon Jul 29 2024 22:57:38 -07:00 [kern_servprocd:info:6834] 0x808deaa00: 0: ERR: Servprocd::SpUpdate: doPreUpdateChecks: Ping to internal SP IP failed.
00000017.02338b6e 0e63406a Mon Jul 29 2024 22:57:38 -07:00 [kern_servprocd:info:6834] 0x808deaa00: 0: NOTICE: Servprocd::SpUpdate: ScheduleSpAutoUpdate: SP Firmware network auto-update using firmware package /mroot/etc/software/SP_FW.zip could not be scheduled.
00000017.02338b6f 0e63406a Mon Jul 29 2024 22:57:38 -07:00 [kern_servprocd:info:6834] 0x808deaa00: 0: NOTICE: Servprocd::SpUpdate: SpUpdateStateHandleEvent: New SP firmware package is locally available, SP auto-update has not been triggered.
00000017.02338b70 0e63406a Mon Jul 29 2024 22:57:38 -07:00 [kern_servprocd:info:6834] 0x808deaa00: 0: NOTICE: Servprocd::SpUpdate: SpUpdateReport: New SP package 4.11P1 is available on local node.
00000017.02338b8d 0e6340cf Mon Jul 29 2024 22:57:48 -07:00 [kern_servprocd:info:6834] 0x80964bf00: 8503e8000155719f: NOTICE: Servprocd::CLI: get_spcs_port : spcs port value in sp_api_service mdb is 50000
00000017.02338b97 0e6340fa Mon Jul 29 2024 22:57:53 -07:00 [kern_servprocd:info:6834] Thrift: Mon Jul 29 22:57:53 2024 TSocket::open() timed out <Host: 192.0.2.80 Port: 50000>
00000017.02338b98 0e6340fa Mon Jul 29 2024 22:57:53 -07:00 [kern_servprocd:info:6834] 0x80964bf00: 8503e8000155719f: ERR: Servprocd::CLI: sp_get_sensor_info_worker : TTX ERROR: 1 (open() timed out)
00000017.02338bae 0e63415e Mon Jul 29 2024 22:58:03 -07:00 [kern_servprocd:info:6834] 0x80964bf00: 8503e8000155719f: NOTICE: Servprocd::CLI: get_spcs_port : spcs port value in sp_api_service mdb is 50000
00000017.02338baf 0e63415e Mon Jul 29 2024 22:58:03 -07:00 [kern_servprocd:info:6834] Thrift: Mon Jul 29 22:58:03 2024 TSocket::open() connect() <Host: 192.0.2.80 Port: 50000>: Host is down
 

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.