CONTAP-87549: Auto-Giveback setting disabled after automated nondisruptive upgrade (ANDU)
Issue
- The auto-giveback and auto-giveback-after-panic settings are disabled on some nodes after an ANDU.
- If auto giveback options are enabled before ANDU, those options are disabled before failover and again enabled by ANDU after giveback.
- Due to a ONTAP bug, these options are not enabled at the end of the upgrade.
- If there is node reboot or panic on any of the nodes, then the node will remain in "Waiting for giveback..." state as auto-giveback options are not enabled.