CONTAP-91776: Shelf firmware repeatedly updates or system displays wrong disk names after upgrade to ONTAP 9.12.1P4 or 9.13.1
Issue
Shelf firmware updates occur every 30 minutes
Tue Jun 27 01:06:13 +0800 [node-02: dsa_disc: sfu.firmwareDownrev.shelf:error]: Shelf 0a.shelf0 has downrev firmware.
Tue Jun 27 01:06:13 +0800 [node-02: dsa_disc: sfu.firmwareDownrev.shelf:error]: Shelf 0a.shelf1 has downrev firmware.
Tue Jun 27 01:17:55 +0800 [node-02: dsa_sfu: sfu.firmwareDownrev:error]: Disk shelf firmware needs to be updated on 2 disk shelves.
Tue Jun 27 01:17:55 +0800 [node-02: dsa_sfu: sfu.downloadStarted:info]: Update of disk shelf firmware started on 2 shelves.
...
Tue Jun 27 01:36:13 +0800 [node-02: dsa_disc: sfu.firmwareDownrev.shelf:error]: Shelf 0a.shelf0 has downrev firmware.
Tue Jun 27 01:36:13 +0800 [node-02: dsa_disc: sfu.firmwareDownrev.shelf:error]: Shelf 0a.shelf1 has downrev firmware.
Incorrect disk name displays
A system displays the disk name as <node_name>:<disk_path> after a disk replacement is performed.