Issue

  • When adding disks to an existing mirrored aggregate using System Manager, an unexpected additional plex (plex0) may be displayed in the RAID layout view
  • Normally, only two plexes (a local and a remote, such as plex1 and plex7) should be shown for a mirrored aggregate.
  • However, the System Manager interface may incorrectly display three plexes (plex0, plex1, and plex7), which can cause confusion for users.
  • This issue is limited to the System Manager GUI display during the disk addition workflow.
  • The underlying aggregate configuration remains correct, and command-line tools and REST API queries to the plex endpoint return the expected plexes.

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.