Answer

  • Although the -auto-giveback setting was disabled with the storage failover modify command, the system still performed an auto-giveback once the node was booted back up because -onreboot was enabled.
  • If the system performs a takeover because the partner node reboots and the -onreboot setting is enabled, the system will always perform an auto-giveback once the partner node is back up, regardless of the -auto-giveback setting being disabled.
  • If auto-giveback was performed due to the -onreboot setting, the following events will be seen in the EMS logs:
... [Node1: cf_main: cf.fsm.autoGBTkoverOnReboot:info]: Failover monitor: Automatic giveback was initiated following a takeover that was caused by the partner reboot.
... [Node1: cf_main: cf.fsm.autoGivebackStarted:info]: Failover monitor: Automatic giveback started
NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.