Unsupported Ethernet switch alert for BES 53248
Applies to
- ONTAP 9
- BES 53248 cluster network switch
Issue
system health alert show
reportsUnsupported Ethernet switch is detected
.
Node: NodeA
Resource: Swtich01
Severity: Major
Indication Time: Mon Jan 16 17:00:52 2023
Suppress: false
Acknowledge: false
Probable Cause: Unsupported Ethernet switch is detected.
Possible Effect: Communication problems and network connectivity issues
occur.
Corrective Actions: Unsupported Ethernet switch "Swtich01"
found. Connect a supported Ethernet switch to the
network.
system switch ethernet show
takes a long time to return the full output and reportsUnsupport Model
for one of the switches
Cluster::*> system cluster-switch show
Switch Type Address Model
--------------------------- ------------------ ---------------- ---------------
Swtich01 cluster-network 192.168.x.x OTHER
Serial Number: Unknown
Is Monitored: false
Reason: Unsupported Model
Software Version: BES-53248A1, 3.4.4.6, Linux 4.4.211-28a6fe76, 2016.05.00.05
Version Source: SNMP