System-level Diagnostic test fail with Unigen NVDIMM
Applies to
- ONTAP 9
- FAS8300/8700
- AFF-A400
Issue
- System-level Diagnostic test fail with Unigen NVDIMM at first try and second try test success.
Fisrt Test:
Memory:
dimm11 16 GB 3200 MT/s 1 Unigen
Diagnostics tool for FAS8300 - Version 07.01.04
Action Id How Name Status
---------- ---- ---------- ------------------------------------------- --------------------------------
RunTest: 1 Foreground MEM:patternverify:NVDIMM Running -------------
Error: no valid data- Slot 11
Error
Second Test:
Diagnostics tool for FAS8300 - Version 07.01.04
Action Id How Name Status
---------- ---- ---------- ------------------------------------------- --------------------------------
RunTest: 1 Foreground MEM:patternstore:NVDIMM Running -------------
Success
- After test and during power cycle system detecte following error:
System will power cycle and wait NVDIMM backup
Running full memory initialization.
DIMM F0: NVDIMM in ERROR condition (status = 00000801).