One of two cluster switches not monitored by CSHM with "IP address not reachable"
Applies to
- ONTAP 9.1P3
- CN1610 cluster interconnect switch
Issue
- After swapping out cluster switches with new ones or after cluster switch maintenance, one of the two cluster-interconnect switches reports it is not monitored by the Cluster Switch Health Monitor (CHSM):
::> system cluster-switch show
Switch Type Address Model
--------------------------- ------------------ ---------------- ---------------
cn1610-sw1 cluster-network 10.1.10.10 CN1610
Serial Number: xxxxxxxxxxx
Is Monitored: true
Reason:
Software Version: 1.2.0.7
Version Source: ISDP
cn1610-sw2 cluster-network 10.1.10.11 CN1610
Serial Number: xxxxxxxxxxx
Is Monitored: false
Reason: IP address not reachable
Software Version: 1.2.0.7
Version Source: ISDP
- Cluster switch is pingable from node-mgmt LIFs.