Skip to main content
NetApp Knowledge Base

Newly added HA pair nodes fail after cluster expansion

Views:
Visibility:
Public
Votes:
0
Category:
ontap-9
Specialty:
core
Last Updated:

Applies to

  • NetApp AFF C60 (Planed additional nodes)
  • NetApp FAS8200 (Existing nodes)
  • NetApp ONTAP 9
  • Storage failover (SFO)

Issue

  • New NetApp AFF C60 nodes are added to an existing ONTAP cluster.
  • Existing nodes show SFO as healthy.
  • Newly added AFF C60 HA pairs do not establish HA.
  • storage failover show reports Takeover Possible as false for the newly added AFF C60 nodes.

cluster1::> storage failover show

                              Takeover
Node           Partner        Possible State Description
-------------- -------------- -------- -------------------------------------
node1          node2          true     Connected to node2
node2          node1          true     Connected to node1
node3          node4          true     Connected to node4
node4          node3          true     Connected to node3
node5          node6          false    Waiting for node6, Takeover is not
                                       possible: Storage failover
                                       interconnect error, NVRAM log not
                                       synchronized, Disk inventory not
                                       exchanged
node6          node5          false    Waiting for node5, Takeover is not
                                       possible: Storage failover
                                       interconnect error, NVRAM log not
                                       synchronized, Disk inventory not
                                       exchanged
node7          node8          false    Waiting for node8, Takeover is not
                                       possible: Storage failover
                                       interconnect error, NVRAM log not
                                       synchronized, Disk inventory not
                                       exchanged
node8          node7          false    Waiting for node7, Takeover is not
                                       possible: Storage failover
                                       interconnect error, NVRAM log not
                                       synchronized, Disk inventory not
                                       exchanged

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.