Newly added HA pair nodes fail after cluster expansion
Applies to
- NetApp AFF C60 (Planed additional nodes)
- NetApp FAS8200 (Existing nodes)
- NetApp ONTAP 9
- Storage failover (SFO)
Issue
- New NetApp AFF C60 nodes are added to an existing ONTAP cluster.
- Existing nodes show SFO as healthy.
- Newly added AFF C60 HA pairs do not establish HA.
storage failover showreportsTakeover Possibleasfalsefor the newly added AFF C60 nodes.
cluster1::> storage failover show
TakeoverNode Partner Possible State Description-------------- -------------- -------- -------------------------------------node1 node2 true Connected to node2node2 node1 true Connected to node1node3 node4 true Connected to node4node4 node3 true Connected to node3node5 node6 false Waiting for node6, Takeover is not possible: Storage failover interconnect error, NVRAM log not synchronized, Disk inventory not exchangednode6 node5 false Waiting for node5, Takeover is not possible: Storage failover interconnect error, NVRAM log not synchronized, Disk inventory not exchangednode7 node8 false Waiting for node8, Takeover is not possible: Storage failover interconnect error, NVRAM log not synchronized, Disk inventory not exchangednode8 node7 false Waiting for node7, Takeover is not possible: Storage failover interconnect error, NVRAM log not synchronized, Disk inventory not exchanged