Skip to main content
NetApp Knowledge Base

Is it possible to connect both data and cluster ports to the same switch?

Views:
146
Visibility:
Public
Votes:
0
Category:
ontap-9
Specialty:
hw
Last Updated:

Applies to

  • ONTAP 9
  • FAS/AFF
  • Cluster network switches

Answer

  • No, it is an unsupported configuration.
  • The cluster network should be a dedicated one. The only possibility it could be shared with is the storage network with the usage of the right RCF if NVME shelves are present.

Additional Information

additionalInformation_text

 

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.