Applies to

  • Cisco C9336C
  • Ontap 9.14.1P11

Issue

  • Following shows "Switch-Health degraded"
::> system health subsystem show
Subsystem Health
----------------- ------------------
SAS-connect ok
Environment ok
Memory ok
Service-Processor ok
Switch-Health degraded
CIFS-NDO ok
Motherboard ok
IO ok
MetroCluster ok
MetroCluster_Node ok
FHM-Switch ok
FHM-Bridge ok
SAS-connect_Cluster ok
13 entries were displayed.

::> system health alert show
Node: sanpc254
Alert ID: SwitchSNMPCommunication_Alert
Resource: sancl201-cs01(XXXXXXXX)
Severity: Major
Indication Time: Tue Apr 22 02:58:38 2025
Suppress: false
Acknowledge: false
Probable Cause: SNMP communication from the node to the ethernet
switch has failed repeatedly. Invalid SNMP settings
are configured with ONTAP Switch Health Monitoring or
on the Ethernet switch.
Possible Effect: Ethernet switch communication problems and
accessibility issues.
Corrective Actions: 1) Check the SNMPv2c community or SNMPv3 username on the Ethernet switch to verify
that the expected community string or username is configured.
To view the expected community string or username, run the "system switch ethernet show -snmp-config" command.
2) (SNMPv3) Verify that the SNMPv3 credentials are present within ONTAP.
To view the established SNMP logins, run the "security login show -application snmp" command.
If a custom engine-id was provided for the SNMPv3 user,
ensure it is same as that of the remote switch.
  • Intermittently seeing a number of SwitchSNMPCommunication_Alert then it gets cleared eventually.
 [?]  Tue Apr 22 12:30:13 +1000 [udcdsanpc254: cshmd: hm.alert.raised:alert]: Alert Id = SwitchSNMPCommunication_Alert , Alerting Resource = sancl201-cs01(XXXXXXXXXX) raised by monitor ethernet-switch
 [?]  Tue Apr 22 12:30:13 +1000 [udcdsanpc254: cshmd: hm.alert.raised:alert]: Alert Id = SwitchSNMPCommunication_Alert , Alerting Resource = sancl201-cs02(XXXXXXXXXX) raised by monitor ethernet-switch
 [?]  Tue Apr 22 13:25:25 +1000 [udcdsanpc254: cshmd: hm.alert.cleared:notice]: Alert Id = SwitchSNMPCommunication_Alert , Alerting Resource = sancl201-cs01(XXXXXXXXXX) cleared by monitor ethernet-switch
 [?]  Tue Apr 22 13:25:25 +1000 [udcdsanpc254: cshmd: hm.alert.cleared:notice]: Alert Id = SwitchSNMPCommunication_Alert , Alerting Resource = sancl201-cs02(XXXXXXXXXX) cleared by monitor ethernet-switc
  • No other alerts just the SwitchSNMPCommunication_Alert
  • No issues getting response from SNMPWalk
  • The network port is experiencing minimal utilization. 

 

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.