Issue

HWASSIST on both nodes is reporting the following error:

Keep Alive Status : Error: did not receive hwassist keep alive alerts from pa rtner."hwassist test" results in a time out.

Pings to both nodes are successful. Storage failover hwassist stats show:

storage failover hwassist stats show  

Node              Alert Type      Alert Event      Count  Takeover    Last Received

---------------- ------------ -------------------- ------ --------- --------------------

hweqecpntap01-02a

                 system_down  power_loss                0 Yes       ---

                 system_down  l2_watchdog_reset         0 Yes       ---

                 system_down  power_off_via_rlm         0 Yes       ---

                 system_down  power_cycle_via_rlm       0 Yes       ---

                 system_down  reset_via_rlm             0 Yes       ---

                 system_down  power_off_via_sp          0 Yes       ---

                 system_down  power_cycle_via_sp        0 Yes       ---

                 system_down  reset_via_sp              0 Yes       ---

                 system_down  post_error                0 No        ---

                 system_down  abnormal_reboot           0 No        ---

                 system_down  loss_of_heartbeat         0 No        ---

                 keep_alive   periodic_message          0 No        ---

                 test         test                      0 No        ---

                 

 

ID_mismatch  ---                     549 ---       Fri Apr  4 18:09:37 EST 2014

                 Key_mismatch ---                       0 ---       ---

                 Unknown      ---                       0 ---       ---

                 Number_of_times_hw_assist_alerts_throttled: 0

hweqecpntap01-02b

                 system_down  power_loss                0 Yes       ---

                 system_down  l2_watchdog_reset         0 Yes       ---

                 system_down  power_off_via_rlm         0 Yes       ---

                 system_down  power_cycle_via_rlm       0 Yes       ---

                 system_down  reset_via_rlm             0 Yes       ---

                 system_down  power_off_via_sp          0 Yes       ---

                 system_down  power_cycle_via_sp        0 Yes       ---

                 system_down  reset_via_sp              0 Yes       ---

                 system_down  post_error                0 No        ---

                 system_down  abnormal_reboot           0 No        ---

                 system_down  loss_of_heartbeat         0 No        ---

                 keep_alive   periodic_message          0 No        ---

                 test         test                      0 No        ---

 

 

                 ID_mismatch  ---                     539 ---       Fri Apr  4 18:09:10 EST 2014

                 Key_mismatch ---                       0 ---       ---

                 Unknown      ---                       0 ---       ---

                 Number_of_times_hw_assist_alerts_throttled: 0

2 entries were displayed.

 

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.