  • ONTAP 9.10.1P4
  • FAS - AFF systems
  • CN1610 cluster network switch

Issue

  • System intermittently reports following type of warning
HA Group Notification (Health Monitor process cshm: ClusterIfIslDownWarn_Alert[XXXXXXXXXXX/ Link Aggregate 1]) ALERT
  • An error for the ports making up the Link Aggregate is displayed in the output of system health alert show
Cluster::> system health alert show
 
Node: Node-01
Resource: Link Aggregate 1
Severity: Major
Indication Time: Wed Aug 17 05:41:50 2022
Suppress: false
Acknowledge: false
Probable Cause: The cable used to connect switch "Switch01/
Link Aggregate 1" to the ISL port might be faulty.
For the port-channel, please check each individual link.
Possible Effect: Cluster redundancy might be lost.
Corrective Actions:
1) Check whether the cable is fully inserted into the interface port on both ends.
2) Reconnect the ISL port using another cable. After
reconnecting it, verify whether the link of the ISL
port is up by executing the commands per the switch
configuration guide or by checking whether the Link
status LED is on.
 
  • The ports effected are 0/13 - 0/16, which are the Inter-Switch Links (ISL) between the cluster network switches
  • The output of show port all on the switch confirms that the ports are all physically down
Admin     Physical   Physical   Link   Link    LACP   Actor
Intf      Type   Mode      Mode       Status     Status Trap    Mode   Timeout
--------- ------ --------- ---------- ---------- ------ ------- ------ --------
0/1              Enable    10G Full   10G Full   Up     Enable  Enable long
--More-- or (q)uit
 
0/2              Enable    10G Full   10G Full   Up     Enable  Enable long
0/3              Enable    10G Full   10G Full   Up     Enable  Enable long
0/4              Enable    10G Full              Down   Enable  Enable long
0/5              Enable    10G Full              Down   Enable  Enable long
0/6              Enable    10G Full              Down   Enable  Enable long
0/7              Enable    10G Full              Down   Enable  Enable long
0/8              Enable    10G Full              Down   Enable  Enable long
0/9              Enable    10G Full              Down   Enable  Enable long
0/10             Enable    10G Full              Down   Enable  Enable long
0/11             Enable    10G Full              Down   Enable  Enable long
0/12             Enable    10G Full              Down   Enable  Enable long
0/13      PC Mbr Enable    10G Full              Down   Enable  Enable long
0/14      PC Mbr Enable    10G Full              Down   Enable  Enable long
0/15      PC Mbr Enable    10G Full              Down   Enable  Enable long
0/16      PC Mbr Enable    10G Full              Down   Enable  Enable long

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.