CONTAP-170009: CRC Errors on XL710 40GbE ports after ONTAP reboot

Views:
63
Visibility:
Customer
Votes:
0
Category:
ontap-9
Specialty:
core
Last Updated:

Issue

  • After an ONTAP reboot or upgrade, the node with XL710-based 40 Gigabit Ethernet cluster ports reports Cluster Network Degraded events.

  • Example:
  • [node1: vifmgr: vifmgr.cluscheck.hwerrors:alert]: Port e8a on node node1 is reporting a high number (at least 1 per 1000 packets) of observed hardware errors (CRC, length, alignment, dropped).

  • 40GbE ports (used for cluster or front-end data) are reporting CRC errors in the RECEIVE section of the ifstat command.

  • interface e8a (0 hours, 5 minutes, 31 seconds) --
    RECEIVE
    Total frames: 23634 | Frames/second: 71 | Total bytes: 2019k
    Bytes/second: 6100 | Total errors: 18292 | Errors/minute: 3316
    Total discards: 0 | Discards/minute: 0 | Multi/broadcast: 92
    Non-primary u/c: 0 | CRC errors: 16978 | Runt frames: 0

  • The 40GbE port link might be flapping or might subsequently go down.

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.