What is the MetroCluster IP switchback procedure?
- Views:
- 243
- Visibility:
- Public
- Votes:
- 0
- Category:
- metrocluster
- Specialty:
- metrocluster
- Last Updated:
- 6/16/2025, 10:38:02 PM
Applies to
- ONTAP 9
- MetroCluster IP (MCC-IP)
Answer
- Forced or negotiated switchover must have successfully completed.
- Power on the controllers at the disaster site.
- If using ONTAP 9.6 or later, verify that automatic healing is completed successfully:
cluster::> metrocluster operation history show
- If auto-healing is not completed, perform aggregate healing manually:
cluster::> metrocluster heal aggregates
cluster::> metrocluster heal root-aggregates
- Data aggregate resynchronization must complete. Check the status:
cluster::> storage aggregate plex show
Note: It can take a few hours or days for this to complete.
- Verify that the controller is ready for a switchback:
cluster::> metrocluster switchback -simulate
- Perform switchback:
cluster::> metrocluster switchback