Link down in dual 40/100G Ethernet T62100-CR card port
Applies to
- MetroCluster IP
- Dual 40/100G Ethernet T62100-CR network card P/N X1146A
- Affected port connected to shared MetroCluster/Cluster network switches
Issue
- Multiple AutoSupport
HA Group Notification (HA INTERCONNECT DOWN) ALERTs SYSCONFIG -AAutoSupport section or ONTAP Command Line Interface (CLI) output::> system node run -node node_name -command sysconfig -ashow one of the T6 card ports "down". Example:
slot 1: Dual 40/100G Ethernet T62100-CR e1a MAC Address: 00:00:00:00:00(auto-100g_sr4-fd-up) QSFP Vendor: FINISAR CORP QSFP Part Number: FTLC9558REPM QSFP Serial Number: A12b3CD e1b MAC Address: 00:10:00:00:00(auto-unknown-fd-down) QSFP Vendor: QSFP Part Number: QSFP Serial Number: - AutoSupport
IFSTAT-Asection or ONTAP CLI output "::> system node run -node node_name -command ifstat e1b" may show incrementing CRC errors on that port or "Media state: no carrier" with a high number of "Up to downs"ifconfig -vvvAutoSupport section or ONTAP CLI output for::> system node run -node node_name -command ifconfig -vvvdetects the transceiver but with the "no carrier" status.
- ONTAP CLI output for
::> metrocluster interconnect show -partner-type HAin offline state- Connected switch port might also get disabled
- Example of ONTAP events for this scenario:
... [node_name: intr: netif.linkDown:info]: Ethernet e1b: Link down, check cable.... [node_name: nchmd: hm.alert.raised:alert]: Alert Id = MccIp_PortOfflineAlert , Alerting Resource = node_name_t6nex1_e1b raised by monitor node-connect... [node_name: mgwd: callhome.hm.alert.major:alert]: Call home for Health Monitor process nchm: MccIp_PortOfflineAlert[node_name_t6nex1_e1b].
- In some scenarios a flapping port situation may be exhibited. Example:
... [node_name: intr: netif.linkUp:info]: Ethernet e1b: Link up.... [node_name: intr: netif.linkDown:info]: Ethernet e1b: Link down, check cable.... [node_name: intr: netif.linkUp:info]: Ethernet e1b: Link up.... [node_name: intr: netif.linkDown:info]: Ethernet e1b: Link down, check cable.... [node_name: intr: netif.linkUp:info]: Ethernet e1b: Link up.... [node_name: nchmd: hm.alert.cleared:notice]: Alert Id = MccIp_PortOfflineAlert , Alerting Resource = node_name_t6nex1_e1b cleared by monitor node-connect