Bridge unreachable in-band
- Views:
- 690
- Visibility:
- Public
- Votes:
- 0
- Category:
- metrocluster
- Specialty:
- metrocluster
- Last Updated:
- 2/10/2022, 12:12:23 PM
Applies to
- ATTO 7500N FibreBridge
- ATTO 7600N FibreBridge
Issue
The Bridge is unreachable in-band and is not responding to in-band commands:
mc1::> system health alert show
Node: mc1-02
Resource: ATTO_2000001086a83308
Severity: Major
Indication Time: Thu Aug 19 20:24:03 2021
Suppress: false
Acknowledge: false
Probable Cause: "ATTO_2000001086a83308" bridge is not reachable over management network.
Possible Effect: Bridge "ATTO_2000001086a83308" cannot be monitored for alerts.
Corrective Actions: 1) If the bridge is monitored by SNMP, verify that the node management LIF is up
by using the "network interface show" command.
Verify that the "ATTO_2000001086a83308" bridge is alive by using the "network ping" command.
2) If the bridge is monitored in-band, check the fabric cabling to the bridge, and then verify that the bridge is powered up.
mc1::> storage bridge run-cli -name ATTO_2000001086a83308 -command "info"
[Job 34738] Job succeeded: Bridge is currently unavailable. Wait a few minutes and then try the operation again.