Skip to main content
NetApp Knowledge Base

System Manager displays partially connected status for igroup

Views:
7,357
Visibility:
Public
Votes:
6
Category:
ontap-9
Specialty:
san
Last Updated:
5/14/2025, 3:15:55 PM

Applies to

  • ONTAP 9.11.x and above
  • SAN

Issue

  • System Manager displays partially connected for igroup and portset:
System Manager displays partially connected
 
  • Alert details identify LIF with the current initiator connection:
    • iSCSI initiator connection
  • EMS log shows:

Partially connected Initiator 'xxxxxxxxxxxxx' is not logged in to any network interfaces on node "node1"

  • FC initiators seem to be logged in to only one of the nodes.

igroup show -instance -vserver v1 -igroup ig1

Vserver Name: v1
Igroup Name: ig1
Protocol: fcp
OS Type: vmware
Portset Binding Igroup: -         
Initiators:21:00:xx:xx:xx:xx:xx (node1) (not logged in)
           21:00:xx:xx:xx:xx:xx (node2) ( logged in)

  • iSCSI initiators show they are logged in:

igroup show -instance -vserver svm_iscsi -igroup iscsi_svm_hv
          Vserver Name: svm_iscsi
           Igroup Name: iscsi_svm_hv
              Protocol: mixed
               OS Type: hyper_v
Portset Binding Igroup: -
           Igroup UUID: 1672833e-ab48-11ef-91b0-d039eabda81a
                  ALUA: true
            Initiators: iqn.1991-05.com.microsoft:hv.example.local (logged in)
iqn.1991-05.com.microsoft:hv.example.local (logged in)

  • LIFs and corresponding ports hosting the LIFs are up and online on both the Nodes on storage end
  • Host login events (scsitarget.fct.portLogin) from affected host logged in on storage EMS related to host/switch reboots

  • missing login events logged from the same initiator, indicating that the host could not establish connection back to storage post reboot of the host:

Fri Dec 22 16:57:02 +0530 [NetApp1: fct_tpd_work_thread_0: scsitarget.fct.portLogin:notice]: Login at target FC port: '0e' by initiator port: 'aa:00:00:10:9b:yy:xy:xx' address 0x106xx. The target virtual port is: 'NetApp FC Target Port (8324) svm:lif_1'.
Fri Dec 22 17:01:48 +0530 [NetApp1: bcomd: san.initiator.login.missing:notice]: Initiator "aa:00:00:10:9b:yy:xy:xx" is not logged in to any LIFs on this node for Vserver "svm", portset "fc_pset_1". Access to LUNs might be disrupted if a failover occurs.
Fri Dec 22 17:16:48 +0530 [NetApp1: bcomd: san.initiator.login:notice]: Missing login for initiator "aa:00:00:10:9b:yy:xy:xx", Vserver "svm", portset "xxx", has been logged on.

  • Initiator is logged into LIF of nodeA but is not logged into LIF of partner node and below error message is seen in EMS logs:
    Initiator "10:00:00:00:aa:xx:yy:xx" is not logged in to any network interfaces on node "Nodeb".
     
  • Initiator is logged into LIFs on both nodeA and nodeB, but the System Manager GUI still reflects partially connected

Node "NETAPP_01" has no logged in initiators.
iqn.1998-01.com.vmware:esx_host1:123456789:64
The initiator isn't logged in to any network interfaces on node "NETAPP_01

Cluster does show the correct number of connections

NETAPP::> vserver iscsi session show
          Tpgroup        Initiator                        Initiator
Vserver   Name    TSIH   Name                   ISID      Alias
--------- ------- ---- ------------------------ --------- ---------------------
SVM1      NETAPP_01_iscsi-01
                     2 iqn.1998-01.com.vmware:esxi_host1:123456789:64
                                                00:00:00:00:00:01
                                                          iscsi_vmk
SVM1      NETAPP_02_iscsi-02
                     1 iqn.1998-01.com.vmware:esxi_host1:123456789:64
                                                00:00:00:00:00:02
                                                          iscsi_vmk

 

 

 

 

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.