CONTAP-95064: Incorrectly reporting 'vol.duplicate.msid' EMS when a load-sharing (LS) relationship is configured
Issue
- After upgrade , EMS starts to send emergency alerts there are duplicate MSIDs on LS mirrors:
[[node-01: mgwd: vol.duplicate.msid:EMERGENCY]: Duplicate MSID "2157483507" has been detected in SVM "svm1". The duplicate MSID is used for volumes "svm1_root_ls01" and "svm1_root".]
[[node-01: mgwd: vol.duplicate.msid:EMERGENCY]: Duplicate MSID "2157483510" has been detected in SVM "svm2". The duplicate MSID is used for volumes "svm2_root_ls01" and "svm2_root".]
- The volumes are cofirmed to be LS mirrors and not a FlexGroup Member:
[::> volume show -msid <msid_number> ]
[::> snapmirror show -vserver <svm_name> -type LS ]
[::> vol show -vserver <svm_name> -volume <volume_name> -fields is-constituent,is-flexgroup ]