After switch reboot ClusterIfIslDownWarn_Alert is seen
Applies to
- ONTAP 9
- Cisco N9K-C9336C-FX2 cluster switch
Issue
- Switch rebooted after a power outage or maintenance.
- You may see this ASUP alert:
HA Group Notification (Health Monitor process cshm: ClusterIfIslDownWarn_Alert[Switch_1(XXXXXXXXXXX)/Ethernet1/35]) ALERT
- The switch health shows degraded:
cluster1::> system health subsystem showSubsystem Health----------------- ------------------SAS-connect okEnvironment okMemory okService-Processor okSwitch-Health degradedCIFS-NDO okMotherboard ok- In event logs:
Thu Apr 10 18:51:19 -0600 [Node_2: cshmd: hm.alert.raised:alert]: Alert Id = ClusterIfIslDownWarn_Alert , Alerting Resource = Switch_1(XXXXXXXXXXX)/Ethernet1/36 raised by monitor ethernet-switchThu Apr 10 18:53:45 -0600 [Node_2: mgwd: callhome.hm.alert.major:alert]: Call home for Health Monitor process cshm: ClusterIfIslDownWarn_Alert[Switch_1(XXXXXXXXXXX)/Ethernet1/35].- The ISL ports come back online on their own.