System health status degraded due to FC bridge port offline
Applies to
- FC Metrocluster
- Brocade G610 FC switch
Issue
- Receive the following alerts in EMS log frequently (multiple times a day)
HA Group Notification (Health Monitor process schm: FabricSwitchUnreachable_Alert[1000xxxxxxxxxxxx]) ALERT
HA Group Notification (Health Monitor process nchm: InterconnectAdapterOfflineAlert[2100xxxxxxxxxxxx]) ALERT
HA Group Notification (Health Monitor process nchm: StorageFCAdapterFault_Alert[1000xxxxxxxxxxxx]) ALERT
HA Group Notification (Health Monitor process schm: NoISLPresentAlert[1000xxxxxxxxxxxx]) ALERT- Storage bridge show reveals errors for two bridges connected to a single FC switch
::> storage bridge show
Is Monitor Managed Is Bridge
Bridge Symbolic Name Monitored Status By Vendor Model Bridge WWN Secure
------------------------ ------------- --------- ------- ------- ------ --------------------- ---------------- ---------
ATTO_2000XXXXXXXXXXXX bridge_a_2
true error in-band Atto FibreBridge 7600N 2000XXXXXXXXXXXX false
ATTO_2000XXXXXXXXXXXX bridge_b_1
true ok in-band Atto FibreBridge 7600N 2000XXXXXXXXXXXX false
ATTO_2000XXXXXXXXXXXX bridge_b_2
true error in-band Atto FibreBridge 7600N 2000XXXXXXXXXXXX false
ATTO_2000XXXXXXXXXXXX bridge_a_1
true ok in-band Atto FibreBridge 7600N 2000XXXXXXXXXXXX false
4 entries were displayed.
- Output of storage bridge show with error-text-list
::> storage bridge show -fields error-text-list
name error-text-list
--------------------- ---------------
ATTO_2000XXXXXXXXXXXX -
ATTO_2000XXXXXXXXXXXX "ATTO_2000XXXXXXXXXXXX(2000XXXXXXXXXXXX):FC_PORT_2 is Offline."
ATTO_2000XXXXXXXXXXXX -
ATTO_2000XXXXXXXXXXXX "ATTO_2000XXXXXXXXXXXX(2000XXXXXXXXXXXX):FC_PORT_2 is Offline."
4 entries were displayed.