Skip to main content
NetApp Knowledge Base

PCS error reported on Brocade switch port with Rx and Tx well within the recommended range

Views:
1,130
Visibility:
Public
Votes:
3
Category:
fabric-interconnect-and-management-switches
Specialty:
brocade
Last Updated:

Applies to

Brocade switches

Issue

  • PCS errors observed on switch ports:
/fabos/cliexec/porterrshow :
          frames     enc    crc    crc    too    too    bad    enc   disc   link   loss   loss   c3timeout   pcs   uncor
       tx     rx     in    err    g_eof  shrt   long   eof     out   c3    fail    sync   sig    tx    rx     err    err         

172:  276    165      0      3      2      0      0      1      0      0      2      0      2       0    0     89.7m   0
  • Tx and RX power are well within the recommended range: 

=============
Slot  5/Port 28:
=============
RX Power:    -6.9    dBm (689.9uW) ​​​​​​
TX Power:    -1.1    dBm (784.2 uW)

  • Below troubleshooting steps can be tried for isolating the issue:
  1. Reseat, clean the cable and SFP on either ends of the connectivity
  2. Clear switch stats (statsclear and slotstatsclear), and observe the port (using porterrshow )
  3. If any further increment on the pcs err counters, perform hardware fault isolation for cable and sfp by following below steps:
  • In order to do fault isolation if the hardware, move the cable to next available port on the switch end and observe for any increments:
  • If the issues follows on new port, replace the cable/patch panel and verify the port counters
  • If the issue does not follow to the new port, then swap the SFP of the affected port with a good known working SFP and see if the errors subsides

 

 

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.