Fan reports as faulty post PSU replacement on Brocade 6510 switch
Applies to
Brocade 6510 switch
Issue
- Post PSU replacement on the switch, PSU reports healthy however its embedded fan reports as faulty under
sensorshow
,psshow
andfanshow
output.
sensorshow :
sensor 1: (Temperature) is Ok, value is 38 C
sensor 2: (Fan ) is Ok,speed is 14673 RPM
sensor 3: (Fan ) is Faulty
sensor 4: (Power Supply) is Ok
sensor 5: (Power Supply) is Ok
psshow :
Power Supply #1 is OK
Power Supply #2 is OK
fanshow :
Fan 1 is Ok, speed is 14673 RPM
Fan 2 is Faulty
- Under
errdump
, below errors are observed:
errdump:
2022/08/05-11:33:52, [EM-1037], 64940, CHASSIS, INFO, switch, PS 2 is no longer faulted.
2022/08/05-11:33:57, [FW-1011], 64943, FID 128, INFO, switch_default, Env Power Supply 2, is above high boundary(High=0, Low=1). Current value is 1 (1 OK/0 FAULTY).
2022/08/05-11:33:58, [FW-1011], 64944, FID 2, INFO, switch, Env Power Supply 2, is above high boundary(High=0, Low=1). Current value is 1 (1 OK/0 FAULTY).
2022/08/05-12:00:11, [HIL-1301], 64945, CHASSIS, WARNING, switch, 1 blower failed or missing. Replace failed or missing blower assembly immediately.