Dell Emulex adapter PLOGI as G-Port
Applies to
- Brocade 300 FC switch
- Dell branded Emulex FC adapter
Issue
- Following an abrupt site power outage Dell Servers do not see SAN boot LUN's using the iDrac - Emulex Adapter BIOS configuration screen.
- ESXi host may show
No boot device available or Operating System detected. Please ensure a compatible boot media is available
. - Port Configuration Page SAN Discovery Target List for LPe35002-M2-D Port Name: 100000109BB8797E may show
The Link is Up. No Targets Found
. - Storage command
::> igroup show -instance
shows the ESXi host Initiators are not logged in to storage. - Brocade
#switchshow
shows the port as aG-Port
.
Index Port Address Media Speed State Proto
==============================================
0 0 0a0000 id N8 Online FC F-Port 1 N Port + 1 NPIV public <<<<< NetApp storage
1 1 0a0100 id N8 Online FC F-Port 1 N Port + 1 NPIV public
2 2 0a0200 id N8 Online FC G-Port
3 3 0a0300 id N8 Online FC G-Port <<<<< ESXi hosts