Skip to main content
NetApp Knowledge Base

Brocade switch with c3 errors on port

Views:
611
Visibility:
Public
Votes:
2
Category:
fc-series
Specialty:
san
Last Updated:

Applies to

Brocade

Issue

  • The output of porterrshow  indicates enc in, crc err, crc g_eof, bad eof, enc out, disc c3 and c3 timeout TX error counters.

          frames      enc    crc    crc    too    too    bad    enc   disc   link   loss   loss   frjt   fbsy  c3timeout
       tx     rx      in    err    g_eof  shrt   long   eof     out   c3    fail    sync   sig                 tx    rx
     =======================================================================================================================
  7:    2.4m   6.3m  76.9k  42.5k  42.3k   0      0    208      1.0g  39      0      0      0      0      0     20      0

  • Only proceed with the solution after completing the troubleshooting steps below.
    • Reseat and clean the cable at both ends, including the patch panel.
    • Reseat the SFPs on both ends.

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.