Skip to main content
NetApp Knowledge Base

Brocade switch port offline and in “No light” state with low Rx power due to faulty cable

Views:
372
Visibility:
Public
Votes:
2
Category:
fabric-interconnect-and-management-switches
Specialty:
brocade
Last Updated:

Applies to

Brocade Switch

Issue

  • Switch port state shows as No_light under switchshow output:

Index Port Address Media Speed  State    Proto
==============================================
 ----- Truncated -----
   5   5   010500   id     4G   No_Light    FC  

  • porterrshow output shows that link fail, loss sig errors are observed

/fabos/cliexec/porterrshow :
frames        enc    crc     crc     too    too     bad     enc   disc    link    loss   loss    frjt    fbsy    c3timeout     pcs      uncor
tx       rx     in     err     g_eof  shrt    long    eof    out    c3      fail   sync    sig                      tx      rx     err     err
130:  403    471       0       0      0       0       0      0       0       0    334       0       5.4k   0       0       0      0       0       0

  • Portshow of the affected port reports offline status:

portshow 5
portDisableReason: None
portCFlags: 0x0
portFlags: 0x21     PRESENT U_PORT DISABLED
LocalSwcFlags: 0x0
portType:  26.0
portState: 2    Offline  
Protocol: FC
portPhys:  4    No_Light     portScn:   2    Offline   
port generation number:    748
state transition count:    11      

  • Fabric logs shows that port being flapped multiple times

Switch 0; Thu Jun  1 19:17:40 2023 IST (GMT+5:30)
19:17:40.873933 SCN Port Offline;rsn=0x2,g=0xf1e           A2,P0  A2,P0  130  NA
19:17:40.873942 *Removing all nodes from port              A2,P0  A2,P0  130  NA
19:22:14.346217 SCN LR_PORT(0);g=0xf1e                     A2,P0  A2,P0  130  NA
19:22:14.396548 SCN Port Online; g=0xf1e,isolated=0        A2,P0  A2,P1  130  NA
19:22:14.396643 Port Elp engaged                           A2,P1  A2,P0  130  NA
19:22:14.396657 *Removing all nodes from port              A2,P0  A2,P0  130  NA
19:22:14.397110 SCN Port F_PORT                            A2,P1  A2,P0  130  NA
19:22:14.444090 SCN Port Offline;rsn=0x2,g=0xf20           A2,P0  A2,P0  130  NA
19:22:14.444095 *Removing all nodes from port              A2,P0  A2,P0  130  NA
19:22:19.256279 SCN LR_PORT(0);g=0xf20                     A2,P0  A2,P0  130  NA
19:22:30.799147 SCN LR_PORT(0);g=0xf20                     A2,P0  A2,P0  130  NA
19:22:30.899258 SCN Port Online; g=0xf20,isolated=0        A2,P0  A2,P1  130  NA
19:22:30.899357 Port Elp engaged                           A2,P1  A2,P0  130  NA
19:22:30.899371 *Removing all nodes from port              A2,P0  A2,P0  130  NA
19:22:30.900041 SCN Port F_PORT                            A2,P1  A2,P0  130  NA    

  • sfpshow reports Rx value is too low

Slot  5/Port 21:
=============
Identifier:  3    SFP
Connector:   7    LC
Transceiver: 6804404000000000 8,16,32_Gbps M5 sw Short_dist
[...]
Vendor Name: BROCADE
Vendor OUI:  00:05:1e
Vendor PN:   57-1000333-01
Vendor Rev:  A
[...]
Temperature: 59      Centigrade
Current:     7.640   mAmps
Voltage:     3327.1  mVolts
RX Power:    -25.1   dBm (3.1  uW)
TX Power:    -1.3    dBm (743.9 uW)

  • Invalid transmit word(ITW) error observed for the port in errdump logs

2022/11/27-00:23:05, [MAPS-1003], 84606, SLOT 2 | FID 128, WARNING, NTTC_X6_108_FAB2, slot10 port38, F-Port 10/38, Condition=ALL_TARGET_PORTS(ITW/min>11), Current Value:[ITW, 237558518 ITWs], RuleName=defALL_TARGET_PORTSITW_11, Dashboard Category=Port Health.
2022/11/27-00:24:05, [MAPS-1003], 84607, SLOT 2 | FID 128, WARNING, NTTC_X6_108_FAB2, slot10 port38, F-Port 10/38, Condition=ALL_TARGET_PORTS(ITW/min>11), Current Value:[ITW, 222669296 ITWs], RuleName=defALL_TARGET_PORTSITW_11, Dashboard Category=Port Health

 

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.