Skip to main content
NetApp Knowledge Base

Brocade SAN switch director CP firmware mismatch

Views:
21
Visibility:
Public
Votes:
0
Category:
fabric-interconnect-and-management-switches
Specialty:
san
Last Updated:

Applies to

  • ONTAP SAN FCP
  • Brocade FC switch Director

Issue

  • After replacement of faulty CP blade the firmware sync process fails due to replacement version outside of requirements
  • Active CP runs FOS 9.2 , standby CP runs FOS 8.2
  • CP blade firmware sync fails
Example:

Errdump -a:
2025/05/08-15:27:24 (CEST), [SULB-1054], 56312, SLOT 2 | CHASSIS, INFO, Brocade_X6-4, Firmwaresync has started

2025/05/08-15:30:14 (CEST), [SULB-1053], 56313, SLOT 2 | CHASSIS, INFO, Brocade_X6-4, Firmware sync to the secondary partition of standby CP has been completed. It will perform auto-reboot followed by auto-commit.

2025/05/08-15:30:27 (CEST), [EM-1033], 56314, SLOT 2 | CHASSIS, ERROR, Brocade_X6-4, CP in Slot 1 set to faulty because CP ERROR asserted.

2025/05/08-15:30:29 (CEST), [EM-1047], 56315, SLOT 2 | CHASSIS, INFO, Brocade_X6-4, CP in slot 1 not faulty, CP ERROR deasserted.

2025/05/08-15:30:34 (CEST), [HAMK-1004], 56316, SLOT 2 | CHASSIS, INFO, Brocade_X6-4, Resetting standby CP (double reset may occur).

2025/05/08-15:30:35 (CEST), [EM-1033], 56317, SLOT 2 | CHASSIS, ERROR, Brocade_X6-4, CP in Slot 1 set to faulty because CP ERROR asserted.

2025/05/08-15:30:36 (CEST), [EM-1047], 56318, SLOT 2 | CHASSIS, INFO, Brocade_X6-4, CP in slot 1 not faulty, CP ERROR deasserted.

2025/05/08-15:31:44 (CEST), [FSSM-1004], 56319, SLOT 2 | CHASSIS, CRITICAL, Brocade_X6-4, Incompatible software version in HA synchronization.

hashow
Local CP (Slot 2, CP1): Active, Cold Recovered
Remote CP (Slot 1, CP0): Standby, Healthy
HA enabled, Heartbeat Up, HA State not in sync

Firmwareshow
Slot Name Appl Primary/Secondary Versions Status
--------------------------------------------------------------------------
1 CP0 FOS v8.2.1c STANDBY
          Unknown           <<< Firmware on second partition is unknown >>>
2 CP1 FOS v9.2.1a ACTIVE *
          v9.2.1a


 

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.