Brocade FC Switch Management Port down
Applies to
Brocade FC Switch
Issue
- Brocade Management Port not reachable, no sending or receiving traffic, no errors in errdump indicate a hardware issue.
- Swapping cables and ports do not resolve the issue
- Checking the port configuration via CLI on Bro cade switch (serial connection):
switch:admin> ethif --show eth0
-
$ ethtool eth0
Settings for eth0:
Supported ports: [ TP MII ]
Supported link modes: 10baseT/Half 10baseT/Full
100baseT/Half 100baseT/Full
Supports auto-negotiation: Yes
Advertised link modes: 10baseT/Half 10baseT/Full
100baseT/Half 100baseT/Full
Advertised auto-negotiation: Yes
Speed: 100Mb/s
Duplex: Full
Port: MII
PHYAD: 1
Transceiver: external
Auto-negotiation: off
Link detected: no - If Port is set to MII, use:
$ mii-tool -vvv:
[...]
eth0: 100 Mbit, full duplex, no link
[...]
basic mode: 100 Mbit, full duplex
basic status: no link
capabilities: 100baseTx-FD 100baseTx-HD 10baseT-FD 10baseT-HD
advertising: 100baseTx-FD 100baseTx-HD 10baseT-FD 10baseT-HD
- Connected switch port on Cisco switch:
#sh int status | in AB04
Gi1/0/15 AB04.AD.01 notconnect 666 full 1000 10/100/1000BaseTX
Gi1/0/16 AB04.AD.02 notconnect 666 full 1000 10/100/1000BaseTX