Skip to main content
NetApp Knowledge Base

SwitchIfDead_Alert on MCC IP cluster switch

Views:
637
Visibility:
Public
Votes:
0
Category:
metrocluster
Specialty:
metrocluster
Last Updated:

Applies to

  • MetroCluster IP
  • BES-53248

Issue

  • Following message received in the EMS log

[Node-01: cshmd: hm.alert.raised:alert]: Alert Id = SwitchIfDead_Alert , Alerting Resource = Switch-01(XXXXXXXXXXXX)/Ethernet0/55 raised by monitor ethernet-switch

  • System health alert with the following error was reported

Cluster::>  system health alert show
               Node: Node-01
           Alert ID: SwitchIfDead_Alert
           Resource: Slot: 0 Port: 55 100G - Level
           Severity: Major
    Indication Time: Mon Jul 14 14:25:11 2025
           Suppress: false
        Acknowledge: false
     Probable Cause: The interface Switch-01/Slot: 0 Port: 55
                     100G - Level is up, but it is not passing unicast
                     traffic.
    Possible Effect: The lack of transmit or receive traffic reported by
                     the switch can indicate issues with port-level or
                     switch-level data packet forwarding.
 Corrective Actions: 1) Check interface counters and neighbor discovery information to verify the port's activity.
                     2) Check cluster and switch health status.

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.