Issue

  • IO errors being received on server end and server is not functioning properly.
  • Multiple LUNs are present to this server through the ONTAP.
  • Below are Error messages seen on Linux host:

[Sun May 18 18:05:06 2025] sd 1:0:1:411: [sdar] tag#149 FAILED Result: hostbyte=DID_ERROR driverbyte=DRIVER_OK cmd_age=1s
[Sun May 18 18:05:06 2025] sd 1:0:1:411: [sdar] tag#149 CDB: Read(16) 88 00 00 00 00 00 00 00 00 00 00 00 00 80 00 00
[Sun May 18 18:05:06 2025] I/O error, dev sdar, sector 0 op 0x0:(READ) flags 0x4200 phys_seg 16 prio class 0
[Sun May 18 18:05:06 2025] qla2xxx [0000:3d:00.0]-301f:1: Dropped frame(s) detected (0x9000 of 0x10000 bytes).
[Sun May 18 18:05:06 2025] sd 1:0:1:418: [sdbq] tag#138 FAILED Result: hostbyte=DID_ERROR driverbyte=DRIVER_OK cmd_age=1s
[Sun May 18 18:05:06 2025] sd 1:0:1:418: [sdbq] tag#138 CDB: Read(16) 88 00 00 00 00 00 00 00 00 00 00 00 00 80 00 00
[Sun May 18 18:05:06 2025] I/O error, dev sdbq, sector 0 op 0x0:(READ) flags 0x4200 phys_seg 16 prio class 0
[Sun May 18 18:05:06 2025] device-mapper: multipath: 252:72: Failing path 66:176.
[Sun May 18 18:05:06 2025] device-mapper: multipath: 252:12: Failing path 68:64.
[Sun May 18 18:05:07 2025] device-mapper: multipath: 252:72: Reinstating path 66:176.
[Sun May 18 18:05:07 2025] device-mapper: multipath: 252:12: Reinstating path 68:64.
[Sun May 18 18:05:07 2025] qla2xxx [0000:3d:00.0]-301f:1: Dropped frame(s) detected (0x3800 of 0xc000 bytes).

  • switchshow  output on switch end for the port 3 is showing online and port 4 is showing Laser_flt.

Index Port Address  Media Speed   State       Proto
==================================================
3   3   010300   id    N16      Online      FC  F-Port  21:00:f4:c7:aa:9c:1f:04 

Index Port Address  Media Speed   State       Proto
==================================================
4   4   010400   id    N16      Laser_Flt   FC
 

  • Tx value is low for both the ports as per sfpshow output.

switch1:admin> sfpshow 3
RX Power:    -3.8    dBm (417.3uW)
TX Power:    -10.8   dBm (83.1  uW)

Switch2:admin> sfpshow 4
RX Power:    -4.8    dBm (332.1uW)
TX Power:    -inf    dBm (0.0   uW)

 

 

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.