Skip to main content
NetApp Knowledge Base

High enc_out errors reported under porterrshow on Brocade switch due to faulty cable

Views:
194
Visibility:
Public
Votes:
0
Category:
fabric-interconnect-and-management-switches
Specialty:
brocade
Last Updated:

Applies to

Brocade switch

Issue

  • High enc_out errors reported under porterrshow output on Brocade switch.
admin> porterrshow 15
frames      enc    crc    crc    too    too    bad    enc   disc   link   loss   loss   frjt   fbsy  c3timeout    pcs    uncor
tx     rx      in    err    g_eof  shrt   long   eof     out  c3    fail    sync   sig                  tx    rx     err    err
15:  291    148    901    137     76      5      0     61 3.9g   0      0      0      0      0      0      0      0      0      0
 
 
  • sfpshow reports both Rx and Tx power is in recommended range.

RX Power:    -2.7    dBm (532.4uW)
TX Power:    -2.1    dBm (617.5 uW)

 

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.