ERR truncating integer value events observed on BES-53248 switch
Applies to
- BES-53248 switches
- Switch uptime over 497 days
Issue
- Without any configuration changes, the switch starts reporting the following errors:
(BES-53248) >en
(BES-53248) #show logging buffered
<187> Jul 8 12:16:42 switch-1 General[procLOG]: snmp_logging.c(1281) 523142 %% ERR truncating integer value > 32 bits
- The switch uptime is more than 497 days:
(BES-53248) #show sysinfo
System Description............................. EFOS, 3.8.0.2, Linux 4.15.18-c1baa8e0, 2016.05.00.05
System Name.................................... CL-Switch-01
System Location................................
System Contact.................................
System Object ID............................... 1.3.6.1.4.1.4413
System Up Time................................. 501 days 9 hrs 36 mins 20 secs
Current SNTP Synchronized Time................. Apr 13 11:16:23 2022 UTC