Continued packet loss when pinging from Cluster LIFs after EFOS upgrade
Applies to
- Cluster Switch BES-53248
- AFF/FAS switched configurations
Issue
- After BES-53248 Cluster switches firmware upgrade packet loss is reported from all cluster LIFs
[?] Tue Jun 17 23:49:29 +0100 [NODE-01: vifmgr: vifmgr.cluscheck.ctdpktloss:alert]: Continued packet loss when pinging from cluster lif NODE-01_clus2 (node NODE-01) to cluster lif NODE-03_clus1 (node NODE-03).
[?] Tue Jun 17 23:49:41 +0100 [NODE-01: vifmgr: vifmgr.cluscheck.ctdpktloss:alert]: Continued packet loss when pinging from cluster lif NODE-01_clus2 (node NODE-01) to cluster lif NODE-03_clus2 (node NODE-03).
[?] Wed Jun 18 00:33:36 +0100 [NODE-01: vifmgr: vifmgr.cluscheck.ctdpktloss:alert]: Continued packet loss when pinging from cluster lif NODE-01_clus2 (node NODE-01) to cluster lif NODE-04_clus1 (node NODE-04).
[?] Wed Jun 18 00:33:48 +0100 [NODE-01: vifmgr: vifmgr.cluscheck.ctdpktloss:alert]: Continued packet loss when pinging from cluster lif NODE-01_clus2 (node NODE-01) to cluster lif NODE-04_clus2 (node NODE-04).
[?] Wed Jun 18 00:34:24 +0100 [NODE-01: vifmgr: vifmgr.cluscheck.ctdpktloss:alert]: Continued packet loss when pinging from cluster lif NODE-01_clus2 (node NODE-01) to cluster lif NODE-02_clus1 (node NODE-02).
[?] Wed Jun 18 00:34:35 +0100 [NODE-01: vifmgr: vifmgr.cluscheck.ctdpktloss:alert]: Continued packet loss when pinging from cluster lif NODE-01_clus2 (node NODE-01) to cluster lif NODE-02_clus2 (node NODE-02).
- There were no CRC errors present before the upgrade
- After the upgrade all of the cluster ports show CRC errors being present
- There are no issues reported with cabling or transceivers on either switches or nodes
- The switch ports in use are 49 to 52