ECC Memory Error Threshold Exceeded on SolidFire H610S
Applies to
- NetApp H610S-4-P (SolidFire All-Flash Array, H-Series)
- SolidFire Element OS v12.9
- Environments with Active IQ monitoring
Issue
- A SolidFire node reported the following hardware alert:
Correctable ECC memory error count crossed threshold on DIMM: CPU0_F0
Sample SEL/BMC Log Output:
17994 Jun/21/2026 00:08:26 [Warning][MemoryErrorDis][EventLoggingDisabled] Correctable ECC Logging Disabled - Asserted17993 Jun/21/2026 00:08:26 [Warning][MemoryError][Memory] Correctable ECC Logging Limit Reached (CPU0_F0) - Asserted17992 Jun/21/2026 00:08:26 [Information][MemoryError][Memory] Correctable ECC (CPU0_F0) - Asserted
The system was online and operational, but the node entered a degraded state.- No maintenance activity was ongoing on the affected node.