E-Series Host Redundancy Lost alert due to incorrect cabling with FC host
Applies to
- NetApp E-Series
- SANtricity OS
- All FC ports are UP
Issue
Recovery Guru
in SANtricity System Manager displaysHost Redundancy Lost
Loss of host-side connection redundancy detected
notification is deliveredRECOVERY-GURU-PROCEDURES.HTML
showsALB_HOST_REDUNDANCY_LOST
Failure Entry N: ALB_HOST_REDUNDANCY_LOST-Recovery Failure Type Code: 475
Storage array: <STORAGE_ARRAY>
Affected host: <HOST>
Affected controller: Controller in bay <A/B>
End of Failure Entry 1: Back to top
STORAGE-ARRAY-PROFILE
andSTATE-CAPTURE-DATA
indicate that 2 FC ports on the host are connecting to the single controllerSTORAGE-ARRAY-PROFILE
>HOST-TO-VOLUME ASSIGNMENTS
shows the host has 2 FC ports
Host: <HOST>
Host type: Windows (clustered or non-clustered)
Interface type: Fibre Channel
Host port identifier: <FC_WWPN_1>
Alias: <ALIAS_1>
Host port identifier: <FC_WWPN_2>
Alias: <ALIAS_2>
Data Assurance (DA) capable: Yes
Large sector size supported: NoSTATE-CAPTURE-DATA
>ionShow
>tditnall 0
from a single controller shows the above 2 FC ports are connecting
...TDITN..:...................................Initiator.....................................:..........IOs..........:........Busy.........Idle
tditn Ch : Location Device Name Port Name Seq : Open Completed Errs : Ms Ms
------ -- :--------- -------------------------------- -------------------------------- ---- :----- ---------- ----- :------------ ------------
..
4 2 : <ALIAS_2> 2000f4c7aa0a471f <FC_WWPN_2> 6 : 0 12 0 : 2356058 0
..
6 3 : <ALIAS_1> 2000f4c7aa0a46f7 <FC_WWPN_1> 4 : 0 1567 0 : 2356058 0