Issue
Controller in Shelf 99, Bay A Status: Online Cache Backup Device Status: Failed Type: SATA flash drive Location: Controller A, Connector SATA 1 Capacity: 8,192 MB Product ID: Sxxxxxxxxxxxx Part number: Not Available Serial number: Sxxxxxxxx Revision level: FW11 Manufacturer: Xxxxx Date of manufacture: Not availableFIRMWARE INVENTORY Storage Array Report Date: 1/1/70, 12:00:00 AM UTC Storage Array Name: xxxxxxxxx Current SANtricity OS Software Version: 11.50.2P1 Management Software Version: 11.52.0000.9007 Controller Firmware Version: 08.52.00.01 Supervisor Software Version: 08.52.00.01 IOM (ESM) Version: 11.52.0G00.0001 Current NVSRAM Version: N280X-852834-D02 Staged SANtricity OS Software Version: None Staged NVSRAM Version: None
Controllers Location: Shelf 99, Bay A Current Firmware Version: 08.80.00.00 -------------> new conroller firmware async failed. Current NVSRAM Version: N280X-852834-D02 Current Supervisor Software Version: 08.80.00.00 Board ID: 2806 Manufacturer sub-model ID: 318
Location: Shelf 99, Bay B Current Firmware Version: 08.52.00.01 Current NVSRAM Version: N280X-852834-D02 Current Supervisor Software Version: 08.52.00.01 Board ID: 2806 Manufacturer sub-model ID: 318