E-series reports Extended Fibre Channel link down
Applies to
- NetApp E-Series system
- Direct Attached
- StorageGRID Appliance
Issue
- Within E-Series support bundle or AutoSupport, the major-event-logreports FC port constantly flapping. Similarly, these events may be found in SANtricity System Manager under Support > Events.
Extended Fibre Channel link down (greater than one minute) - Host-side: controller in bay A, port 5
Fibre channel link down - Host-side: controller in bay A, port 5
Fibre channel link up - Host-side: controller in bay A, port 5- Within E-Series support bundle or AutoSupport, the fcDumpcommand output in thestate-capture-datafile may show a high amount of bad characters:
2806-A           Our  Num  ::...Exchange Counts...:: Num  ..Link Up.. 
Chip   LinkStat  Port Port ::                     :: Link  Bad  Bad
                  ID  Logi ::Open    Total  Errors:: Down  Char Frame
 2-Src Up-Ptp      e8    2 ::  0     236987      0::    2    19     0
 3-Src Up-Ptp      e8    3 ::  0       4553      1::   27 139145    0