E-series DRAWER_DEGRADED status changes between Degraded and Optimal
- Views:
- 459
- Visibility:
- Public
- Votes:
- 0
- Category:
- e-series-systems
- Specialty:
- esg
- Last Updated:
- 1/25/2022, 9:19:24 AM
Applies to
- E5600
- SANtrciicty OS 08.40.60.01
Issue
- Recovery Guru reports
DRAWER_DEGRADED-Recovery Failure Type Code: 393
- The status for a particular drawer flips for a certain amount of time between Degraded and Optimal as seen in the Major Event Log (MEL) :
A:12/22/21 1:51:37 PM (12:51:37) 401931 2860 The drawer's status is optimal - Tray 1, Drawer 4 A:12/22/21 1:51:25 PM (12:51:25) 401930 285f A drawer in the tray has become degraded - Tray 1, Drawer 4 <--CRITICAL A:12/22/21 12:23:05 PM (11:23:05) 401876 2860 The drawer's status is optimal - Tray 1, Drawer 4 A:12/22/21 12:22:54 PM (11:22:54) 401875 285f A drawer in the tray has become degraded - Tray 1, Drawer 4 <--CRITICAL A:12/22/21 12:17:47 PM (11:17:47) 401873 2860 The drawer's status is optimal - Tray 1, Drawer 4 A:12/22/21 12:17:13 PM (11:17:13) 401872 285f A drawer in the tray has become degraded - Tray 1, Drawer 4 <--CRITICAL A:12/22/21 12:08:53 PM (11:08:53) 401869 2860 The drawer's status is optimal - Tray 1, Drawer 4 A:12/22/21 12:08:41 PM (11:08:41) 401868 285f A drawer in the tray has become degraded - Tray 1, Drawer 4 <--CRITICAL A:12/22/21 12:08:07 PM (11:08:07) 401866 2860 The drawer's status is optimal - Tray 1, Drawer 4 A:12/22/21 12:07:56 PM (11:07:56) 401865 285f A drawer in the tray has become degraded - Tray 1, Drawer 4 <--CRITICAL A:12/22/21 12:00:34 PM (11:00:34) 401864 2860 The drawer's status is optimal - Tray 1, Drawer 4
- The issue is not constantly present