E-Series SNMP linkDown trap during drive replacement
Applies to
- NetApp E-Series
- NetApp SANtricity OS
- Simple Network Management Protocol (SNMP) monitoring
- Controller management port (Ethernet port 1 and port 2)
- NetApp StorageGRID storage node with E-Series controller
Issue
- SNMP linkDown trap is received by the monitoring system after drive replacement.
- Monitoring system raises an alert for the E-Series storage node:
.1.3.6.1.6.3.1.1.5.3 Normal "Status Events" 10.1.2.3 - .1.3.6.1.6.3.1.1.5.3 linkDown
A linkDown trap signifies that the SNMP entity...
- Major Event Log (MEL) reports management port link down and link up events on controller A:
A:10/30/26, 5:35:53 AM (05:35:53) 36423 5801 Management port link down - Shelf 99, Bay A
A:10/30/26, 4:21:07 AM (04:21:07) 36405 5802 Management port link up - Shelf 99, Bay A
- Recovery Guru reports no failure entries.
- Management port 1 operates normally:
Ethernet port: 1
Link status: Up
Negotiation mode: Auto-negotiate
Port speed: 1000 Mbps
Duplex mode: Full duplex
Network configuration: Static
IP address: x.x.x.x
- Management port 2 reports a link status of Down:
Ethernet port: 2
Link status: Down
Negotiation mode: Auto-negotiate
Port speed: Unknown
Duplex mode: Half duplex
IPv4 settings: Enabled
IP address: x.x.x.x